噪音引起的听力损失

神秘爆炸电容器的情况

3d预测专家引起的听力损失索赔中的索赔人参与了对被告制造的照相照明设备的检查和测试;他声称自己在被测设备中的电容器时经常受到3d预测专家的干扰“爆炸了”在他的耳朵几英寸之内。

A 雀科 acoustic engineering expert was instructed by the parties to advise the Court on the likely noise exposure. This was an unusual case, and no published information could be found on the likely levels of noise produced by exploding electronic components.

雀科’我们的专家与Buxton健康与安全实验室合作,在安全的条件下进行了声学测试,在此期间,将相关类型的大型充油电解电容器放置在测试单元中,并通过施加过电压对其进行了测试,以测试其是否损坏。通过这些测试,专家可以计算出索赔人可能要承受的日常个人3d预测专家暴露水平(LEPd)和瞬时峰值声压水平。